UPS 1200G SERIES MULTI MODULE SYSTEMS
<ul>The Cat Flywheel UPS provides our highest efficiency continuous power solution (>97% efficient). This technology uses a power dense integrated flywheel, which stores sufficient energy to ride through power disturbances such as dips or surges in voltage and/or current. The stored power is immediately available for delivery to a critical load during a power disturbance. This system provides ample ride-through time and allows for an orderly walk-in of the generator set to assume the load for the duration of the disturbance. The integrated flywheel design is modular, supporting easy expansion to meet future power quality/power protection requirements<br>The Cat Flywheel UPS delivers lower operating costs due to several factors, including lower maintenance and replacement costs, the space savings associated with a reduced footprint (up to 75% smaller than a battery based UPS system) and a yearly energy efficiency improvement of 4%. <br> With the Flywheel UPS, you also benefit from reduced upkeep and maintenance, field-proven mechanical energy storage that is predictable and fail-safe, nearly unlimited life with no fall-off in performance and a broad operating temperature range up to 104° F. And this technology is environmentally friendly, posing no safety hazards to either your personnel or the environment.</ul>
SPECIFICATIONS
Rated Power300 kVA (240 kW) - 1200 kVA (960 kW)
System EfficiencyUp to 98%
Energy StorageFlywheel


technical summary
Rated Power300 kVA (240 kW) - 1200 kVA (960 kW)
System EfficiencyUp to 98%
Energy StorageFlywheel
UPS 1200Z STANDARD EQUIPMENT
- flywheel energy storage
- igbt based bidirectional converter
- integral modem – remote communication
- local emergency power off epo
- remote notification and monitoring via ethernet and email
- rs232 or rs485 serial connection
- ups viewreal time monitoring software
- 10” color touchscreen operator interface
- programmable input and output contacts
- topbottom cable entry
- back feed protection
- redundant control power
- monitoring and alarms for all critical components wselfdiagnostics
- voltage regulation and power factor correction
- harmonic cancellation
- static bypass switch
- high overload capacity
- superior power conditioning
- redundant cooling fans
UPS 1200Z OPTIONS
- 24volt dc generator set starting power
- 4wire input and output
- remote status panel 8 status led’s
- remote emergency power off repo
- remote snmpmodbus monitoring
- ability to parallel up to 7 systems
- redundant flywheel and ups
- external synchronization input
- separate bypass input
- external maintenance bypass control
- field expandable